Germany (English)
Change
Search
HOME
CATNIC
PRODUCT RANGE
DOWNLOAD CENTRE
CONTACT
ONLINE SERVICES
Plaster profile
Interior plaster profiles
Interior plaster profiles
Fast drying plaster profiles / undercoat rails
Plaster-separating / stop profiles
Plaster stop profiles
Exterior plaster profiles
Exterior plaster / plaster stop profiles
Plaster stop profiles / roof ventilation profiles
Plaster stop profiles
Base profiles
Dry wall profiles
Dry wall profiles (PVC)
Drywall enclosing profiles (PVC)
Dry wall profiles (aluminium / steel)
Dry wall profiles (PVC)
WDVS (Heat insulation sandwich system) profiles
Base profiles
Expansion joint profiles
Mesh corner bead
Wire corner bead
Wire corner bead
Expansion joint profiles
Expansion joint profiles
Combination -expansion joint profiles
Expansion joint profiles with protective film
Mesh
Interior plaster mesh
Universal mesh
Exterior plaster mesh
Exterior mesh
Full heat protection mesh
Armoured mesh
Soffit profile
Standard
Flexible pull-off strip
Added-on protective lip
Accessories
Embrasure joint profiles gel
Catnic sealing system
Systems
Individual components
Accessories
XL system extensions
Catnic Sealing Profile Gel
Expanded rib metals
Galvanized sheet steel
Non-corrosive stainless steel
Curved elements
Verona
Milano
Accessories
Wall connector
Non-corrosive stainless steel
Galvanized sheet steel
INFORMATION
SHOPPING CART
MY CATNIC
Individual components
Please select a type from the following range:
Items per page:
5
10
20
Sort by:
Article number ascending order
Article number descending order
Page:
1 of 1
Catnic sealing system for exterior
The sealing strip 3040 A with the green foam sealing tape is fixed to the exterior of the window.
According to the. RAL guideline, this function level is to be rendered wind-proof and more open to diffusion of condensates, impact rain resistant and permanent than the interior function layer. Moisture from the function level must be able to escape to the exterior.
For wet plaster and WDVS. Airtight (wind tight) according to DIN 4108-2, EnEv §5 (1), tested to DIN EN 12214. rain impact resistance according to DIN 18355, Section 3 No. 3.5.3, tested similar to DIN EN 1027. sd-Value < 25 m. Movement take-up three-dimensional 3 mm. Elastic seal lip.
Segmented pull-off strip.
[Art.-No. 3040-A]
Catnic sealing system for interior
The sealing strip 3040 I With the red foam adhesive tape
is fixed
to the interior of the window.
According to the RAL-guideline, this function layer is to be applied more air-tight, condensate diffusion resistant and permanent than the outer function layer.
Air tight according to DIN 4108-2, EnEv §5 (1),tested to DIN EN 12114. sd-Value > 100m. Movement take-up three-dimensional 3 mm. Elastic sealing lip.
Flexible pull-off strip.
[Art.-No. 3040-I]
Catnic sealing system for exterior
The sealing strip 3340-A with the green foam sealing tape is fixed to the exterior of the window.
According to the. RAL guideline, this function level is to be rendered more wind-proof and more open to diffusion of condensates and permanent than the interior function layer. Moisture from the function level must be able to escape to the exterior.
For wet plaster and WDVS. Airtight (wind tight) according to DIN 4108-2, EnEv §5 (1),tested to DIN EN 12214. Rain impact resistance according to DIN 18355, Section 3 No. 3.5.3, tested similar to DIN EN 1027. sd-value < 25 m. Movement take-up three-dimensional 3mm. Elastic seal lip.
Segmented pull-off strip.
[Art.-No. 3340-A]
Catnic sealing system for interior
The sealing strip 3340-I with the red foam adhesive tape
is fixed
to the interior of the window.
According to the RAL-guideline, this function layer is to be applied more air-tight, condensate diffusion resistant and permanent than the outer function layer.
Air tight according to DIN 4108-2, EnEv §5 (1),Tested to DIN EN 12114. sd-value > 100m. Movement take-up three-dimensional 3 mm..
Elastic sealing lip.
Flexible pull-off strip.
[Art.-No. 3340-I]
Catnic sealing system for exterior
The sealing strip 3440 A with the green foam sealing tape is fixed to the exterior of the window.
According to the. RAL guideline, this function level is to be rendered more wind-proof and more open to diffusion of condensates and permanent than the interior function layer. Moisture from the function level must be able to escape to the exterior.
Airtight (wind tight) according to DIN 4108-2, EnEv §5 (1), tested to DIN EN 12214. Rain impact resistance according to DIN 18355, Section 3 No. 3.5.3, tested similar to DIN EN 1027. sd Value < 25 m. Movement take-up three-dimensional 3 mm. Elastic seal lip.
This article can also be used for 9 mm.
[Art.-No. 3440-A]
Are you looking for a special article in our range? Please make a selection:
Product group
Plaster profile
Mesh
Soffit profile
Catnic sealing system
Expanded rib metals
Curved elements
Wall connector
All products in the overview
Your shopping cart is empty.
Go to the online shop
Please complete the fields to gain access.
Username
Password
Login
Lost username or password?
Do you want to benfit from the online services of Catnic for the first time?
Register here to do so.
Register
Current product catalogue
Datasheets
Test reports
To the download centre